ArrowStik® Modules
Selecting the ArrowStik Pattern
The Central Controller is designed to offer user selectable trafc directing and trafc warning ash patterns. Each of the ArrowStik functions (LEFT,
CENTER-OUT, RIGHT or FLASH) can be programmed individually for unique patterns and ash rates. This allows the greatest exibility when
controlling the various light bar congurations available. The light bar can be ordered with a 5, 6, 7 or 8 lighthead conguration. The light bar
will come from the factory with the Building Fast pattern as the default for LEFT, CENTER-OUT and RIGHT. The default pattern for FLASH is the
Standard Flash. If it is desired to change the pattern for any of the functions, follow the programming procedure below.
STEP 1:
Power-up the light bar. Select the ArrowStik function that you wish to program (LEFT, CENTER-OUT, RIGHT or FLASH).
Make sure +12v is only applied to the function you are trying to program - otherwise program function will not
operate.
STEP 2:
Continue applying power to the wire from Step 1. Refer to Table 2 for the available ash patterns.
Scroll to the next ash pattern by momentarily holding the Pattern Select wire (BLK/RED) to +power for ~1 sec. The light bar will stop ashing when
the wire is connected to +power. Release the wire and the next pattern as listed in Table 2 will begin to ash. The new pattern is automatically
stored each time.
Notice that for the LEFT, CENTER-OUT and RIGHT functions there are four pattern choices (Building, Building with 3 Flash for the end lightheads,
Traveling Ball with 3 Flash for the end lightheads, and Build/Collapse) and three speeds (Fast, Medium and Slow). There are a total of twelve
possible selections for each function and then you return to the top selection.
For the FLASH function there are nine trafc warning patterns available. Flash patterns marked with an asterisk “*” can be selected in Fast, Medium
or Slow ash rate.
NOTE: To restore the Factory Default ArrowStik Flash Patterns, hold the BLK/RED wire to +power for ~four
seconds.
STEP 3:
Repeat steps 1 through 2 for the other ArrowStik functions as desired.
TRAFFIC DIRECTING / TRAFFIC WARNING FLASH PATTERNS
Mode LEFT CENTER-OUT RIGHT FLASH
1 Building Building Building Standard Flash*
2 Building, 3 Flash Building, 3 Flash Building, 3 Flash Quad Flash Standard
3 Traveling Ball, 3 Flash Traveling Ball, 3 Flash Traveling Ball, 3 Flash Simultaneous Flash*
4 Build/Collapse Build/Collapse Build/Collapse Quad Flash Simultaneous
5 Even/Odd Flash*
6 Quad Flash Even/Odd
7 Left/Right Flash*
8 Quad Flash Left/Right
9 Traveling Ball Flash*
All Patterns have a fast,
medium, or slow speed.
All Patterns have a fast,
medium, or slow speed.
All Patterns have a fast,
medium, or slow speed.
Patterns with the * have a fast,
medium, or slow speed.
Table 2