Code-3 Solex User Manual Page 4

  • Download
  • Add to my manuals
  • Print
  • Page
    / 12
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 3
Selecting Flash Patterns
Use the following instructions for lightbars without programmable light head pairs.
Note: For lightbars equipped with programmable light head pairs refer to the following:
If the lightbar has all single color light heads, please see supplement T16406 (800Series
Software).
If the lightbar has any multi-color light heads, please see supplement T54006 (950Series
Software).
STEP 1
Select the desired 3-Level mode to program by applying +power to the appropriate wire in the 16 conductor cable.
There are seven possible 3-Level modes (see Table 1). The factory default is different for each of the 3 -Level modes. The standard progressive
switch will use the Level-1, Level-2 and Level-3 modes. The defaults for Level-1, Level-2 (L1 + L2) and Level-3 (L1 + L2 + L3) are identied in Table
1A. When using individual switches, make sure to select patterns for all switch combinations.
3-LEVEL MODES OF OPERATION
MODE NUMBER WIRES ACTIVATED
L1 GRN/BLK (LEVEL-1)
L2 WHT/BLK
L1 + L2 GRN/BLK & WHT/BLK (LEVEL-2)
L3 RED/BLK
L1 + L3 GRN/BLK & RED/BLK
L2 + L3 WHT/BLK & RED/BLK
L1 + L2 + L3 GRN/BLK, WHT/BLK, & RED/BLK (LEVEL-3)
Table 1
STEP 2
Observe the ashing pattern operation and determine which pattern is in operation. Refer to Table 1A. This table shows the available ash pat-
terns. Note: the Factory Default is different and identied in the table for each of the ash mode Levels (L1, L2, L3). Once the ash pattern has been
determined, proceed to Step 3
.
STEP 3
Scroll to the next ash pattern by momentarily holding the Pattern Select wire (BLK/RED) to +power for ~1 sec. The light bar will stop ashing when
the wire is connected to +power. Release the wire and the next pattern as listed in Table 1A will begin to ash. The new pattern is automatically
stored each time. Repeat this procedure for each of the seven possible 3-level modes.
NOTE: To restore the Factory Default Emergency Warning Flash Patterns (see Table 1A), hold the pattern select
wire to +power for ~four (4) seconds.
SEE FLASH PATTERN SELECTION NOTES ON FOLLOWING PAGES
Make sure +12v is only applied to the function you are trying to program - otherwise program function will not
operate.
This Product contains high intensity LED powered devices. To prevent eye damage,
DO NOT stare into light beam at close range.
WARNING!
Page view 3
1 2 3 4 5 6 7 8 9 10 11 12

Comments to this Manuals

No comments